After two generations of home-built pinch valves – first the pneumatic pinch valves and then the updated sanitary design – the brewery now runs on industrial pinch valves from AKO: five VMC valves on the main pump’s manifold.
Why? A thin-walled silicone hose burst while we were flushing the brewery with tap water – a bit of operator error plus a software bug. Luckily it was only water, not PBW or wort, but we wanted everything sturdier, so we moved to reinforced MTG Brewart hoses with crimped tri-clamp ends. Our own pinch valves closed by squeezing the soft silicone hose itself – that doesn’t work on a hose with a 5 mm reinforced wall, so the valves needed their own sleeve. An expensive upgrade, but it felt necessary.



Only EPDM and stainless touch the wort
Inside the valve the wort only meets a food-grade EPDM sleeve and the stainless tri-clamp ends. The housing is powder-coated aluminium, but it sits outside the sleeve and never touches the wort. When the valve opens, the sleeve is a straight, smooth tube – nothing for grain or hop debris to hang on to, and easy to clean in place.
| Type | AKO VMC20.04HTECK.50T.30LX |
| Size | DN 20 |
| Connections | Tri-clamp 34 mm (DIN 32676 row A), stainless 1.4404 / 316L |
| Sleeve | EPDM HTEC, food grade |
| Temperature | AKO lists −10 to 90 °C, 120 °C short term (SIP possible) – see below |
| Housing | Aluminium, powder coated (not in contact with the wort) |
| Max. operating pressure | 5.5 bar |
| Control air | Max. 8 bar, G 1/8″ port; at least 2.5 bar above the line pressure to close |
| Weight | 0.6 kg |
| Cleaning | CIP, SIP, piggable |
| Food contact | Manufacturer’s confirmation: FDA, BfR, EC 1935/2004 |
About the temperature: AKO has lowered the listed continuous temperature since we bought ours. We asked, and AKO confirmed that the valves still handle 100 °C – which matters when hot wort and cleaning solution go through them.
A power cut closes everything
A pinch valve is closed by compressed air around the sleeve. Each valve gets its air from a small 12 V pilot valve in a rack, and we deliberately chose normally open pilot valves: without power they let the air through. So if the power goes, every pinch valve closes – nothing drains, and nothing ends up in the wrong kettle. To open a valve, the controller energises its pilot.
A ventilated hood for the pilot valves
The flip side is that an open valve means an energised coil, and 5 W per coil adds up when valves are held open for a whole mash. We built a hood around the pilot valve rack with a 40 mm fan. The brewery controller runs the fan whenever any pilot is energised, and keeps it going for ten minutes after the last one switches off.