New pinch valves from AKO

Posted by

–

After two generations of home-built pinch valves – first the pneumatic pinch valves and then the updated sanitary design – the brewery now runs on industrial pinch valves from AKO: five VMC valves on the main pump’s manifold.

Why? A thin-walled silicone hose burst while we were flushing the brewery with tap water – a bit of operator error plus a software bug. Luckily it was only water, not PBW or wort, but we wanted everything sturdier, so we moved to reinforced MTG Brewart hoses with crimped tri-clamp ends. Our own pinch valves closed by squeezing the soft silicone hose itself – that doesn’t work on a hose with a 5 mm reinforced wall, so the valves needed their own sleeve. An expensive upgrade, but it felt necessary.

Only EPDM and stainless touch the wort

Inside the valve the wort only meets a food-grade EPDM sleeve and the stainless tri-clamp ends. The housing is powder-coated aluminium, but it sits outside the sleeve and never touches the wort. When the valve opens, the sleeve is a straight, smooth tube – nothing for grain or hop debris to hang on to, and easy to clean in place.

TypeAKO VMC20.04HTECK.50T.30LX
SizeDN 20
ConnectionsTri-clamp 34 mm (DIN 32676 row A), stainless 1.4404 / 316L
SleeveEPDM HTEC, food grade
TemperatureAKO lists −10 to 90 °C, 120 °C short term (SIP possible) – see below
HousingAluminium, powder coated (not in contact with the wort)
Max. operating pressure5.5 bar
Control airMax. 8 bar, G 1/8″ port; at least 2.5 bar above the line pressure to close
Weight0.6 kg
CleaningCIP, SIP, piggable
Food contactManufacturer’s confirmation: FDA, BfR, EC 1935/2004
Data from AKO’s product page.

About the temperature: AKO has lowered the listed continuous temperature since we bought ours. We asked, and AKO confirmed that the valves still handle 100 °C – which matters when hot wort and cleaning solution go through them.

A power cut closes everything

A pinch valve is closed by compressed air around the sleeve. Each valve gets its air from a small 12 V pilot valve in a rack, and we deliberately chose normally open pilot valves: without power they let the air through. So if the power goes, every pinch valve closes – nothing drains, and nothing ends up in the wrong kettle. To open a valve, the controller energises its pilot.

A ventilated hood for the pilot valves

The flip side is that an open valve means an energised coil, and 5 W per coil adds up when valves are held open for a whole mash. We built a hood around the pilot valve rack with a 40 mm fan. The brewery controller runs the fan whenever any pilot is energised, and keeps it going for ten minutes after the last one switches off.