How much CO₂ does it take to purge a can?

Posted by

–

Before the LoDoFiller™ fills a can, it flushes the air out with CO₂. The less oxygen left in the can, the better – but every gram of CO₂ spent on a can adds up over a batch. So we put the oxygen probe inside a can and measured what’s left after purges of different lengths.

In short:

  • One second of purge left 3 % oxygen in the can, two seconds 0.4–0.7 % and three seconds 0.1–0.16 %.
  • Beyond about 5 g of CO₂ there was little more to gain: 0.02–0.04 %, close to what the sensor can tell from zero.
  • Throttling the outlet or splitting the purge into pulses didn’t help.
  • We settled on three seconds – about 4 g of CO₂ per can.

The test can

To see inside, we used a transparent 330 ml PET can with a trace-range oxygen spot on the inside of the wall, read from the outside through the plastic with the optical fibre. The meter runs its own profile for it, “TRACE 330 can”, with its own calibration.

The purge

The filler head seals against the can. CO₂ at about 2 bar comes in through a 3–4 mm nozzle in the centre of the head, pointing down, level with the top of the can. The gas leaves through a channel in the upper part of the head, about 20 mm above the rim, and out through a few decimetres of 6 × 1 mm tube and a DN6 pinch valve. After the purge a small valve lets the can down to atmospheric pressure, and then we read the oxygen.

The tests were run from Home Assistant by a script that opens the CO₂ valve and the outlet for a set time, and the CO₂ scale shows how much gas each purge used. The flow turned out to be about 1.3 g a second – more than the 1 g we had estimated.

Results

PurgeCO₂ usedO₂ left in the can
1 s1.4 g3.0 %
2 s2.8–2.9 g0.44–0.66 %
3 s4.0–4.2 g0.11–0.16 %
4 s5.0 g0.041 %
5 s6.8 g0.027 %
10 s12.9 g0.024 %
Two 1 s pulses2.8 g0.50 %
2 s, a minute’s wait, 2 s5.4 g0.060 %
3 s, then 3 s again7.8 g0.039 %
All the cans from 30–31 January 2026, read at about atmospheric pressure after the purge.

The first seconds do most of the work. One second took the can from 21 % to 3 %, and each second after that took away a smaller share. From about 5 g of CO₂ there was little more to gain: 5 and 10 seconds both ended around 0.02–0.03 %, where we suspect the sensor has a small zero offset.

Throttling and pulses. Throttling the outlet only made the purge slower, and two short pulses did no better than one continuous purge of the same length. The two cans with a slow fall to 2–4 % were the throttled ones – with the outlet throttled, the pressure falls slowly. Purging twice with a pause in between worked, but not better than one longer purge of the same CO₂. Unlike in the dry-hop tower, the reading stayed flat after the purge – an empty can has no hops for the oxygen to seep out of.

Our setting. We settled on three seconds, about 4 g of CO₂ per can, which leaves 0.1–0.15 % oxygen. Going to five seconds would cut that to about 0.03 % for another 3 g.

What the numbers don’t tell

These are the numbers for an empty can before filling. When the beer goes in, it pushes most of the gas out through the outlet, so the purge sets the starting point rather than the oxygen in the finished can. We also cap on foam – the lid goes on while foam fills the top of the can – so the headspace is mostly emptied of the gas that was in the can during filling too. Measuring a filled and sealed can is the next step.