Most of the time a fermenter needs cooling, but now and then it needs heat – a yeast that likes it warm, a diacetyl rest at the end of fermentation, or a room that’s colder than the beer should be. Our glycol chiller can only take heat away, so the F80 needs a heater as well.
Until this summer we used Brewtools’ immersion heater, which goes into the tank through a 2″ tri-clamp port. It works, but it’s one more thing inside the beer that has to be cleaned, and there’s only so much room in an F80: we wanted that port for Brewtools’ density meter, which we read straight into Home Assistant. So the heat now comes from the outside, through the stainless, from small heating pads stuck to the cone.
Our first idea was a single heating mat shaped to fit the cone – we drew it as the cone band laid out flat – but the manufacturer was so slow that it never happened. Small pads off the shelf turned out to be the quicker way.

Small pads on the cone
The pads are self-adhesive polyimide film heaters, 94 × 40 mm and 15 W at 24 V. We placed eight of them, in pairs, between the tri-clamp ports on the upper part of the cone, just below the cylinder and its cooling jacket – above the yeast that settles in the cone, so the warmed beer rises through the whole batch. With the F80 upside down in its stand, the cone was easy to get at.
Spread out like this the heat is very gentle: 15 W over 38 cm² is about 0.4 W/cm², a small fraction of what an immersion element runs at. The pads stick on by themselves; the aluminium tape over them is mainly there to spread the heat, but it also covers the edges so they don’t come loose when we handle the insulation jacket.
| Heating pads | QUARKZMAN polyimide film heater, self-adhesive |
| Size | 94 × 40 mm |
| Rating | 24 V, 15 W, 0–120 °C |
| Number | 8 – 120 W in total |
| Supply | Tufvassons PVS 151 safety transformer, 230/24 V AC, 150 VA |
| Switching | Solid-state relay with zero-crossing, on the 230 V side |






24 volts on the tank
The pads run on 24 V AC from a Tufvassons PVS 151 safety transformer – 230/24 V, 150 VA – so there’s nothing at mains voltage on the tank itself. Eight pads draw 5 A, comfortably inside the transformer’s 6.3 A.
The fermenter’s Raspberry Pi switches the transformer’s 230 V side through a solid-state relay with zero-crossing.

Slow PWM and a P-controller
The heating is a simple P-controller with slow PWM. Every 30 seconds the controller works out a duty cycle from how far below the setpoint the beer is: full power one degree under, and a 20 % base so the temperature actually reaches the setpoint instead of settling just below it. Above the setpoint the heat is off.
error = set_temp - mean_temp
duty = min(1.0 * error + 0.2, 1.0) if error > 0 else 0.0
heater_on = (time.time() % 30) < duty * 30 # 30 s PWM period
Heating and cooling never run at the same time: with Heating enabled switched on in Home Assistant, the cooling pump to the fermenter is blocked, while the chiller keeps its glycol cold. The temperature we regulate on is a weighted mean of the top and bottom sensors, and the agitator helps: in auto mode it runs faster while we heat, so the heat from the cone is carried up through the beer.
Does it work?

In the first full run, with about 75 litres of water in the F80 and the agitator running, the target went from 24 to 26 °C. At full power the water warmed by 1.3 °C an hour. In theory 120 W heats 75 litres of water by about 1.4 °C an hour, so most of the heat ends up where it should. The fermenter’s energy meter, which covers everything from the Raspberry Pi up, showed about 9 W at rest and 145 W with the pads on – so the heating takes about 135 W from the wall: 120 W in the pads and the rest lost in the transformer.
The run also shows why the controller has a base duty. As a pure P-controller, the heat tapered off as the water got close to the setpoint, and in the last hour it gained only a tenth of a degree. We added the 20 % base that evening, and 50 minutes later the water was at 26 °C.
And the 2″ port that the immersion heater used to sit in is free for the density meter.