A fermenter you can weigh tells you two things. When you fill it, the weight gives you the volume. And once the yeast gets going it gives you the gravity: the CO₂ that leaves through the spunding valve is weight the beer loses, so a scale under the tank can follow the fermentation in real time without anything touching the beer.
Our first version, back in 2023, was a bathroom scale stripped down to its four load cells. The F80 now stands on a scale of its own: a welded stainless frame on three 100 kg load cells, with an ESP32 that reports to Home Assistant.

The frame
We drew the frame in CAD and welded it from stainless flat bar. It rests on three shear-beam load cells, each on an adjustable foot – three points, so it never rocks, whatever the floor is like. The cables are gathered in a junction box on the frame.









| Load cells | SC8320C shear beam, three of them |
| Capacity | 100 kg each |
| Output | 2.0 mV/V |
| Combined error | 0.02 % of full scale |
| Repeatability | 0.01 % of full scale |
| Creep | 0.02 % of full scale in 30 minutes |
| Temperature effect | 0.0016 % FS/°C on the output, 0.002 % FS/°C on zero |
| Excitation | 5 V (12 V max) |
| Safe overload | 150 % |
The electronics
The first electronics, in 2025, ran on an ESP32-S3 with a small round touch screen and read all three cells through a single ADC. In May 2026 we rebuilt them on ESPHome: an ESP32-C3 with one HX711 per load cell, a DS18B20 temperature sensor on each cell, and an AM2302 that measures the temperature and humidity around the scale. Everything shows up in Home Assistant like any other sensor.


Each load cell is read five times a second. The firmware keeps the last 30 readings, throws away the six highest and the six lowest and averages the rest, so a knock or a vibration doesn’t show up as a change in gravity. The three cells are then added up and calibrated together, with known weights in steps up to almost 30 kg. The temperature of each cell is logged, but not used for anything yet.
Three modes
The scale can’t tell water from wort, beer or a bag of hops, so we tell it what’s going on with a mode in Home Assistant:
- Volume – the gravity is fixed (we type it in), and the weight gives the volume. This is the mode for filling.
- Fermentation – the volume is fixed, and the weight gives the gravity. When we switch to it, the scale waits ten seconds for the weight to settle and takes it, with the gravity we’ve typed in, as its reference.
- Add/Remove – gravity and volume are frozen while we take a sample, dump yeast or add dry hops, so weight that has nothing to do with the fermentation doesn’t end up in the gravity. Back in Fermentation, the scale carries on from where it was.
volume = weight / (sg_ref * 1000) # Volume mode, weight in grams
sg = weight / weight_ref * sg_ref # Fermentation mode
The demands are high: for a 75-litre batch, one gravity point (0.001) is 75 g – out of some 125 kg on the load cells.
How well does it work?

Batch #24 in January shows both what the scale can do and where it stops. While the yeast is busy and CO₂ streams out through the spunding valve, the gravity from the weight follows the hand measurements – between samples it drifted by at most about three points. Early on it reads high: the first CO₂ dissolves in the beer instead of leaving it, all the more under spunding pressure.
Once the valve stops opening, the scale has nothing to go on. The same happens whenever we keep the CO₂ in: when we raise the spunding pressure, the valve stays shut and the gravity stands still until it opens again. So we still measure by hand and feed the result back into the scale several times per batch. A button in Home Assistant logs each hand measurement next to the scale’s own value – those are the dots in the chart.
The weak spot: humidity
On paper these load cells are excellent. In practice they’re far more sensitive to humidity than the cells in the old bathroom scale: when the humidity in the room changes, the weight follows – hours later. In batch #24 the room went from about 10 to 25–30 % RH around day 10, and the gravity from the scale crept up by three points. The first electronics had the same problem, so it points at the load cells rather than the electronics – of all our scales, only the bathroom scale was unbothered.
That’s why the new electronics have a humidity sensor next to the load cells. For now it only logs, so we can see how the weight follows the humidity – correcting for it will have to wait until we understand it better.
Volume and gravity go to Home Assistant and Grafana, next to the temperature, the spunding activity and the dissolved oxygen – more about that in a coming post.
Going forward we’ll also log the gravity with Brewtools’ density meter, which we read straight into Home Assistant. It goes in the 2″ port that the immersion heater used to take, and measures the beer itself – so it doesn’t depend on CO₂ leaving the tank, and the scale gets a second opinion. We have no data from it yet; we’d rather build than brew, as you may have noticed.