  • [OLD] Sanitary pinch valves, updated design

    [OLD] Sanitary pinch valves, updated design

    , ,

    This post describes one of our earlier pinch valve designs – see New pinch valves from AKO for the valves we use today. Discover Our Redesigned Pinch Valves We’ve upgraded our original pneumatic pinch valves with a durable anodized aluminum body, offering enhanced longevity and effortless cleaning. Take a look at the original design here.

  • [OLD] Venturi pipe for flow measurements

    [OLD] Venturi pipe for flow measurements

    , ,

    This post describes one of our earlier flow meters – see Goodbye venturi – flow measurement with the ifm SM6020 for the one we use today. As we were going through the brewery’s hose system and replacing the sanitary valves, we also found the need to upgrade our flowmeter to a larger size. We started…

  • [OLD] Pneumatic pinch valves

    [OLD] Pneumatic pinch valves

    ,

    This post describes one of our earlier pinch valve designs – see New pinch valves from AKO for the valves we use today. Due to our constant pursuit of enhancing our system, we began reevaluating hoses and flows within the brewing system. The design of the previous servo-pinch valves had dictated the placement of the…

  • [OLD] CIP-lid for the brewery

    [OLD] CIP-lid for the brewery

    , ,

    This post describes an earlier version of our brewery – see The Brewery for how it looks today. These days only the fermenter gets a spray ball – see Cleaning the F80 in place. We use a CIP-ball for the fermenter and it works really great. We would like to use CIP on our kettles…

  • [OLD] Sparge arm/mash manifold

    [OLD] Sparge arm/mash manifold

    ,

    This post describes an earlier version of our brewery – see The Brewery for how it looks today. We have used the “standard” sparge arm that is designed for the MLT but we wanted something that was more dynamic and gave room for stirring the bed if necessary so we designed a ring of 12…

  • [OLD] Digital “suction” sensor

    [OLD] Digital “suction” sensor

    , ,

    This post describes our first suction sensor – see Measuring suction under the grain bed for the one we use today. Many brewers use manometers or clear hoses at the bottom of the MLT to monitor the pressure below the grain bed. We have taken it to the next level and put a differential pressure…

  • [OLD] The servo valves

    [OLD] The servo valves

    This post describes one of our earlier valve designs – see New pinch valves from AKO for the valves we use today. These valves are now retired and replaced with Pneumatic pinch valves. About the only thing we salvaged from our first brewery, the Brewie B20, was the servo valves for 16×12 mm silicone hose.…

  • [OLD] Temperature sensor system

    [OLD] Temperature sensor system

    , ,

    This post describes an earlier version of our brewery – see The Brewery for how it looks today. We use six temperature sensors in the brewery for measuring the We use 1.5″ thermo wells for HLT, mash bottom and boil, and custom built sensor probes for mash inlet and outlet (after cooler).The reason for using…

  • [OLD] DIY Counterflow Cooler

    [OLD] DIY Counterflow Cooler

    ,

    This post describes an earlier version of our brewery – see The Brewery for how it looks today. At first we used a plate heat exchanger but they are a pain to clean and not very effective so we made our own counterflow cooler out of 9 m of 12 mm copper tubing, some reinforced…

  • [OLD] Venturi pipe for flow measurements

    [OLD] Venturi pipe for flow measurements

    , ,

    This post describes one of our earlier flow meters – see Goodbye venturi – flow measurement with the ifm SM6020 for the one we use today. This system is now updated with a bigger version! We started with a traditional flow sensor with an impeller but it was not accurate enough and was kind of…