We left the oxygen probe in the beer for 30 days, from pitching to packaging. The yeast kept it at zero – until it stopped working.

We oxygenated a starter and a batch with the oxygen probe in the wort, and watched the yeast take it all within an hour.

We put the oxygen probe inside a can in the LoDoFiller and measured what’s left after purges from one to ten seconds.

We put the oxygen probe in the dry-hop tower and the CO₂ bottle on a scale, and tried four ways of purging.

The original silicone gaskets in our sight glasses let in six to seven times more oxygen than EPDM. So we made our own.

Tubing, valves and ball locks let oxygen into the fermenter too – and a single connection can add as much as a day of steady ingress.

We built a small test chamber and measured how much oxygen gets through tri-clamp gaskets, valves and sight glasses – from 2 to 98 µg per hour.